Kenmore Fridge Not Cooling? 5 DIY Tech Fixes to Save Your Food!

Professional DIY troubleshooting for a Kenmore 795 series refrigerator not cooling.

Kenmore Refrigerator Not Cooling? 5 Easy DIY Fixes (2026)

I see the Kenmore 795 series fail every summer when the humidity spikes and the owners haven't cleaned their coils in years. These LG-built units look sleek, but their linear compressors struggle under the heat. This field report breaks down the Repair Master strategy for 2026, moving from basic airway checks to high-voltage inverter diagnostics. If the fridge is silent, the heart isn't beating, and we need to find out why.

1. The Diagnostic Hierarchy: Field Observations

Experience shows that 60% of cooling calls are due to blocked air or dust, not a blown motor. I always follow a rigid hierarchy to avoid replacing expensive parts on a unit that just needs a vacuum.

Airway and Ventilation

The 795 and 106 model prefixes require specific internal clearances to maintain 37°F in the fresh food section.

  • Internal Vents: Bulky groceries often block the rear air vents. This stops the evaporator fan from pushing cold air.
  • External Clearance: The condenser needs at least 2 inches of space. Without this, the unit cannot shed heat, and the compressor temperature spikes.

The Condenser Coil Heat Sink

Dust acts as an insulator on the condenser coils.

  • Observation: I’ve seen compressors lock up just because a layer of pet hair covered the bottom fins.
  • Action: Unplug the power cord. Vacuum the coils under the fridge. This simple maintenance prevents the compressor from overheating.

Door Gasket Integrity (The Dollar Bill Test)

A leaky gasket allows humid air to enter, which then condenses on the evaporator.

  • Test: Close the door on a dollar bill. If the bill slides out without resistance, the magnetic seal has failed.
  • Fix: Clean the rubber with warm, soapy water. I use a hairdryer on low heat to reshape the rubber so it grips the frame again.

2. Technician’s Logic: Error Code Cheat Sheet

The Main Electronic Control Board (MECB) monitors the RPM of the fans and the resistance of the sensors. When it detects a fault, it flashes a code.

Error Code Component Root Cause Tech Fix
Er, IF Ice Fan Moisture shorts the circuit board in the door duct. Replace the fan and the MECB.
Er FF Evaporator Fan The fan loses its feedback signal for >65 seconds. Test for 12V DC at the motor.
Er CF Condenser Fan Debris stalls the rear fan motor. Clean the motor and test for 12V DC.
Er dH Defrost Heater The heater circuit remains open. Measure R = 30-60\Omega at the heater.
Er FS Freezer Sensor The thermistor data falls out of range. Check NTC resistance values.
The Er IF code is a notorious board killer. If moisture enters the fan duct, it shorts the fan and sends a surge back to the MECB. I always replace both parts at the same time to prevent the new fan from frying the new board.
Visualizing the Er IF error code cause in Kenmore refrigerators.

3. High-Level Testing: Thermistors and Multimeters

The MECB makes every cooling decision based on NTC (Negative Temperature Coefficient) thermistors. These sensors are the eyes of the system.

The NTC Thermistor Math

To verify a sensor, I place it in an ice water bath. As the temperature drops, the resistance must increase according to a specific curve.

  • At room temperature, 77°F (25°C), the resistance should be 10k\Omega.
  • At freezing 32°F (0°C), the resistance should be 30k\Omega.

I calculate the deviation (D) using this formula:


If D > 10\%, I scrap the sensor and install a new one.

Testing Kenmore refrigerator thermistor resistance in an ice water bath.

The PTC Start Relay (The Flip Test)

For non-linear models (Whirlpool 106 prefix), the start relay is a common failure point. I pull the relay off the compressor and check the M (Main) and S (Start) ports with a meter set to Omega.

  1. Upright Position: The meter shows an open line (OL).
  2. Inverted Position: Gravity drops the internal contact. The meter should now show 0 - 1 \Omega.

If the resistance stays infinite (R = \infty) while upside-down, the internal pill has shattered, and the relay is dead.

4. The Linear Compressor Crisis: CON201 Inverter Test

LG-built Kenmore Elites (795 models) use linear compressors that oscillate a piston rather than spinning a crankshaft. These inverters operate at variable frequencies between 10 Hz and 150 Hz. When these systems fail, the compressor draws 0 amps despite the board calling for cooling.

The CON201 Voltage Check

To rule out a faulty motherboard, I perform the CON201 test. This isolates the PCB from the compressor.

  1. Power off the unit and disconnect the CON201 harness from the PCB.
  2. Power on the unit and push the Test 1 button on the board.
  3. Check the AC voltage across terminals 1 and 4 after 30 seconds.

The multimeter should read:


If the board produces 200 VAC but the fridge remains warm, the compressor has a mechanical failure. If the voltage is 0 V, the motherboard is faulty.

Performing the CON201 inverter voltage test on a Kenmore 795 series motherboard.

5. Personal Experience: The Technician's Hack

The Hair Dryer Trick

A no-cooling complaint often stems from an iced-over evaporator. I see this happen if someone leaves the door open or the defrost heater fails.

  1. Remove the back panel in the freezer to expose the coils.
  2. Use a hairdryer on low heat to melt the frost wall blocking the fan.
  3. Check the drain tube. If the tube is frozen, water will leak into the fridge.

This manual defrost saves a $200 service call, but if the ice returns in two weeks, you must replace the defrost heater (30-60\Omega) or the thermal fuse.

6. Smart Field FAQ

Q: Why does my fridge click and then stay silent?

A: This is the sound of the overload protector tripping. The compressor tries to start, draws too much current, and the protector cuts power to prevent a fire. This usually means the start relay is fried or the compressor is locked.

Q: The freezer is at 0°F, but the fridge is at 55°F. What’s wrong?

A: The damper motor has likely failed. This motorized door regulates airflow between compartments. If you hear quiet clicking or rattling from the top of the fridge, the plastic gears in the damper assembly are stripped.

Q: Can I bypass the door switch to test the fans?

A: Yes. I enter Diagnostic Test Mode by pressing the door switch 3 times within 2 seconds of plugging the unit in, then holding it a 4th time. This triggers the fans even with the doors open, so I can see if the motors spin at the correct RPM.

7. The Repair Master Summary

A technician's job is to prove a part is bad before replacing it. I start with the airway and coils, then move to the error codes. If the display shows Er FF or Er CF, I verify the 12V DC power to the fans. For 795 models with a linear compressor, I skip the ohm tests and go straight to the CON201 voltage check. If the board pushes 200 V but the compressor pulls 0 amps, the motor is dead.

Finally, I use the 50% Rule: If the repair costs more than half of a new fridge, I recommend replacement. A linear compressor replacement costs $700–$1,250, while a new unit averages $1,500. If the fridge is over 10 years old and the compressor dies, I tell the customer to go shopping instead of fixing it.

🔍 Technician's Choice: Repair or Replace?

Before you spend $1,000 on a sealed system repair, compare the failure rates and costs across the big three brands: